Use
Capillary flue gas thermometer TKS is intended to be used for direct measuring of flue gas temperature in fireplace flue and other heating equipment that do not allow direct access to the flue pipe. Thermometer's a range of 0 ÷ 600°C.
TOO COLD – imperfect combustion in the heating system; vapour and tar condensate in the smoke pipe and in the chimney
– optimal combustion of fuel in the heating system
TOO HOT – fuel is burned inefficiently, excessive heat loss
The temperature must be evaluated in the operating state of the heating system, not in the case of heating up.
Reading from TRS must be performed in the operating state of the heating system not while heating up.
Technical details
Scale range |
0 ÷ 600°C |
Measuring range |
50 ÷ 400°C |
Accurancy |
±10 °C |
Capíllary length |
1000 mm |
Head diameter |
60 mm (64 mm including the frame) |
Colourway |
blac/blue/white/red |
Technical drawings
Optional accessories for easy installation
Optional accessories for easy installation
Installation box