Thermostat wells

Description


Thermostat well is intended for installation in designated device (e.g. electrical boiler, water heater). Installation is done by screwing the well neck to device coat using suitable sealing. To install the thermostat, insert it into the well of suitable size and secure it by M4 bolt (thermostat series TH 160).

Installing thermostat series TH 140, place its head before securing the lock-nut. Do not rotate the thermostat head when lock-nut is secured as this can damage the thermostat.

Maximum working pressure is PN 6 according to ČSN 130010. All manufactured thermostat wells are subjected to pressure leak test by air under water.

Technical data

Thermostat type
L [mm]
L1 [mm]
TH 140 337 360
TH 140 ZP 16 107 130
TH 141 287 310
TH 143 337 360
TH 144 287 310
TH 160 324 336
TH 160.1 324 336
TH 160.2 324 336
TH 162 110 122
TH 163 110 122
TH 164 170 182
TH 165 170 182
TH 166 210 222
TH 167 260 272
TH 169 324 336

Dimensional drawings

TH 160 well
TH 140 well

 

Photos of the product

Others from category Accessories

Do you need help? Contact us!