Manotherm MTCC 60

Combined device for pressure and temperature measurement in applications where measuring place is different from place of reading. Manometric part can be used to measure pressure of liquids and gases that do not crystallize, and do not cause corrosion of copper alloys.

Description


Manometer consists of plastic casing, manometric system for pressure measurement and thermometric system for temperature measurement. Systems are placed on separate base plate.

Installation and maintenance


Manotherm installation is done by inserting the manotherm head into the hole with dimensions as mentioned in dimensional drawing, by connecting the pressure sensor to pressure source and fastening the cap screw and by inserting the temperature sensor in a thermometer well. Manometer head can be used in any position. To avid capillary vibration it is necessary to fix it at two or more points approximately equally spaced along the capillary. The manotherm does not require any maintenance.

Technical data

Thermometric part
Measuring range 20 to 100°C
Scale range 0 to 120 °C
Scale division 2 K
Accuracy ±4 % from scale range
Sensor dimension Ø 6 x 35,5 mm
Time constant 15 s
Capillary length 1 450 mm
Minimal bending radius of capillary Rmin = 5 mm
Manometric part
Scale range 0-4 bar
Scale division 0,1 bar
Accuracy class ±2,5 % from scale range
Sensor dimension M14x1 or G1/4
Capillary length 920 mm

Accessories


Clack valve ZV4.x (not part of delivery).

Dimensional drawings

Photos of the product

Do you need help? Contact us!